– 15 –
Adjustment Location:
CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin and GND on
CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the ^ button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape ( ) in the
center of the waveform can be clearly distinguished.
L3
CT3
MW
TRACKING
ADJUSTMENT
L4
LW
FREQUENCY
COVERAGE
ADJUSTMENT
CT1
L1
FM
TRACKING
ADJUSTMENT
L2
FM
FREQUENCY
COVERAGE
ADJUSTMENT
LW
TRACKING
ADJUSTMEN
T
L3
CT5
– tuner board (component side) –
π
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.