HCD-EC59
4
CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, the electrical discharge is necessary for the electric shock prevention.
Connect the resistors referring to the fi gure below.
• MAIN board (C622, C626)
Both ends of respective capacitors.
800 :/2 W
800 :/2 W
MAIN Board (Conductor Side) –
C622
C626
MAIN BOARD SERVICE POSITION
• SIDE PANEL (L) was removed.
MAIN board
– Rear side view –