469
Displaying device attributes
Select a box or control panel bank in the list and press the 
attribute display on/off button at the top right of the 
screen to display the attributes of the selected box or 
control panel bank on the right side.
Recovering from mismatches
If there is a mismatch between the obtained configuration 
information from a detected device and the configuration 
information managed by MLS Manager, an error will be 
displayed. Press the [Recover Mismatch] button to 
recover from mismatches.
Configuring an Island
You can assign M/E boxes and cross-point boxes to an 
island and check the local interface connections between 
the assigned boxes.
Do not perform a connection check during normal system 
op
eration.
1
Open the MLS Manager Home > System > Island > 
Island Config menu (60211.02).
2
In the list on the left, select an assignment destination 
physical box ID.
3
In the list on the right, select a box to assign to the 
island.
4
Press the [Assign] button.
To release a box assignment
Press the [Release] button to release the box 
assi
gnment for the selected physical box ID.
5
Press the [Check Local I/F] button.
The [Check Local I/F] window appears.
6
Press the [Check Now] button.
A check of the local interface connections between 
t
he assigned M/E boxes and cross-point box is 
performed.
7
View the check results.
Port Status
Displays the wiring check results and connection 
de
stination port information.
 (OK icon): W
iring check results are consistent
 (Error icon): W
iring check results are 
inconsistent
 (Error icon) + “(Not Exist)”: 
Unable to check 
wiring because there is no module on the port
 (Error icon) + “(No Connection)”: U
nable to 
check wiring because the module on the port is 
no
t connected
Signal Status
Displays the signal quality check results.
 (OK icon): S
ignal quality check results are OK
 (Error icon): Si
gnal quality check results 
indicate an error
 (Error icon) + “(Not Exist)”: 
Unable to check 
signal quality because there is no module on the 
po
rt
If an error occurs, check the box wiring and then press 
t
he [Check Now] button again to execute a 
connection check.
To sort the box list display
You can press a display item title in the list on the right to 
so
rt the display. Pressing a title switches between 
ascending and descending order each time you press the 
title, and [v] (ascending) or [V] (descending) is displayed 
on the right side of the title.
Type: So
rt by box type
Hostname: 
Sort by box host name
Setting the Island Format
You can set the system frequency, reference signal 
format, and cross-point box signal format of an island.
In a 1M/E box switcher configuration, set using the Home 
> S
etup > System > Format/Config > Format menu 
(19101.22) on each switcher.
For details about settings, see “Setting the Signal Format 
and Frequency” (page 364).
Setting the system frequency
You can set the system frequency of a switcher 
configured from multiple boxes in an island.
1
Open the MLS Manager Home > System > Island > 
Format menu (60211.03).
2
In the [Frequency] group, select a system frequency.
59.94: S
elects 59.94 Hz.
50: S
elects 50 Hz.
Note
Note
Note