SAFETY
CHECK-OUT
(US Model)
After
correcting
the
original service
problem,
perform
the
following safety
check
before
releasing
the
set
to
the
customer:
Check
the
antenna
terminals,
metal
trim,
"metallized"
knobs,
screws,
and
all
other
exposed
metal
parts
for
AC leakage.
Check
leakage as described below.
LEAKAGE
TEST
TC-K555ES
3. Measuring the voltage
drop
across
a resistor by
means
of
a YOM
or
battery-operated
AC
volt-
meter.
The
"limit"
indication
is
0.75
V,
so
analog
meters
must have an
accurate
low-
voltage scale.
The
Simpson
250
and Sanwa
SH-63Trd are
examples
of
a passive YOM
that
is suitable. Nearly all
battery
operated
digital
multimeters
that
have a 2V
AC
range are
suitable. (See Fig. A)
The
AC leakage from
any
exposed
metal
part
to
earth
ground
and
from all exposed metal
parts
to
any
exposed
metal
part
having a
return
to chassis,
must
not
exceed
0.5 rnA
(500
microampers).
Leakage
current
can be measured by
anyone
of
three
methods.
I.
A
commercial
leakage tester,
such
as
the
Simpson 229
or
RCA WT-540A.
Follow
the
manufacturers'
instructions
to
use
these
instru-
ments.
2. A
battery-operated
AC milliammeter.
The
Data
Precision 245 digital
multimeter
is
suitable for
this
job.
To
Exposed
Metal
Parts
on
Set
1.5kH
..L Earth
Ground
AC
voltmeter
(0.75
V)
MODEL
IDENTIFICATION
-
Specification
Label
-
SON~
MODEL
NO. TC-K555ES
TAPECORDER
SERIAL
NO.
MADE
IN
JAPAN
US,
Canadian model: AC 120 V 60
Hz
26 W
Fig. A. Using an
AC
voltmeter
to check
AC
leakage.
SON~
MODEL
NO.
TC-K555ES
TAPECORDER
SERIAL
NO.
MADE
IN
JAPAN
AEP model: AC 220 V ~ 50/60
Hz
26 W
UK
model: AC 240 V
~
50/60
Hz
26 W
E model: AC 110, 120, 220, 240 V
~
50/60
Hz
26 W
-3-