4
Adjust
BIAS
until
both
meters
indicate
equal
playback
levels.
A
high
reading
on
the
upper
meter
indicates
a
low
bias
current.
A
low
reading
on
the
upper
meter
indicates
a
high
bias
current.
:
7
An
equal
reading
on
both
meters
indicates
the
optimum
bias
current
condition.
5
Adjust
REC
LEVEL
CALIBRATION
until
both
meters
reach
the
recommended
level
(REC
CAL).
Recommended
level
The
bias
current
is
now
adjusted
to
the
optimum
level
and
the
tape
sensitivity
compensation
has
been
set.
Press
I,
then
set
CALIBRATION
to
OFF.
Rewind
the
tape
and
start
the
actual
recording.
st-lexedgeltatemm
ste
iel-lir4-ielolamer-|
ilelectareln
Although
bias
currrent
and
equalization
are
automatically
set
by
the
Automatic
Tape
Selection
(ATS)
function
for
the
tape
being
used,
you
can
use
the
REC
EQ
CAL
switch
to
change
the
recording
characteristics
according
to
the
nature
of
the
source
material
or
to
compensate
for
the
particular
characteristics
of
the
tape.
:
To
emphasize
higher
frequencies
in
recordings
For
normal
recordings
To
dampen
higher
frequencies
in
recordings
Bias
calibration
recording
Use
the
REC
EQ
CAL
switch
in
conjunction
with
the
BIAS
control
to
modify
bands
of
sound
and
record
according
to
the
tape's
characteristics.
¢
When
recording
music
which
has
strong
middle
and
low
frequencies
Set
the
bias
at
flat
with
the
REC
EQ
CAL
switch
set
in
the
HIGH
position
to
increase
the
bias
current.
Adjust
the
BIAS
control
so
that
the
HIGH
and
LOW
meters
indicate
equal
readings.
¢
When
recording
music
which
has
strong
high
frequencies
Set
the
bias
at
flat
with
the
REC
EQ
CAL
switch
set
in
the
LOW
position
to
decrease
the
bias
current.
Adjust
the
BIAS
control
so
that
the
HIGH
and
LOW
meters
indicate
equal
readings.
Note
With
metal
tape,
because
the
amount
of
frequency
characteristic
modulation
is
not
in
proportion
to
that
of
the
bias,
the
optimum
bias
current
may
not
be
obtained
using
the
methods
above.
Another
use
of
the
REC
EQ
CAL
switch
When
using
special
tapes,
adjusting
the
BIAS
control
with
the
REC
EQ
CAL
switch
set
in
the
NORMAL
position
may
not
result
in
equal
readings
on
the
HIGH
and
LOW
meters.
If
this
occurs,
adjust
the
BIAS
control
after
setting
the
REC
EQ
CAL
switch
to
HIGH
or
LOW.