INSTRUCTION AND SERVICE PARTS MANUAL - FREEZER CS 800, s/n F0176-00 - ALFRED & CO
L3
• When the dasher motor load indicator reaches the first pre-set sensing
level (set at 100% of the motor load) an alarm bell is sounded and the
hot gas valve will automatically open. (this set point can not be changed)
• If the dasher motor load indicator reaches the second pre-set sensing
level (set at 105% of the motor load) the compressor and the dasher will
stop. ( this set point cannot be changed )
• The operator is therefore alerted and should take corrective action
immediately to prevent this stop.
• As the dasher motor load indicator retreats, the alarm bell will stop.
• To obtain the desired output, adjust the speed of the pumps by turning
the pump crank counter-clock-wise to increase the output and
clockwise to decrease the output.
CAUTION !
Change the speed of the pumps only while the pumps are in operation.
• When the pipes and other product-contact surfaces have cooled to
product temperature, check for overrun and stiffness; make the
necessary adjustments to archive the desired product.
• Adjust the overrun with the overrun controller (pos.7).
• Adjust the viscosity with the viscosity controller (pos. 9).
• The mix flow meter gives the mix flow rate expressed in litres per hour.