INSTRUCTION AND SERVICE PARTS MANUAL - FREEZER CS 800, s/n F0176-00 - ALFRED & CO
L3
When the dasher motor load indicator reaches the first pre-set sensing
level (set at 100% of the motor load) an alarm bell is sounded and the
hot gas valve will automatically open. (this set point can not be changed)
If the dasher motor load indicator reaches the second pre-set sensing
level (set at 105% of the motor load) the compressor and the dasher will
stop. ( this set point cannot be changed )
The operator is therefore alerted and should take corrective action
immediately to prevent this stop.
As the dasher motor load indicator retreats, the alarm bell will stop.
To obtain the desired output, adjust the speed of the pumps by turning
the pump crank counter-clock-wise to increase the output and
clockwise to decrease the output.
CAUTION !
Change the speed of the pumps only while the pumps are in operation.
When the pipes and other product-contact surfaces have cooled to
product temperature, check for overrun and stiffness; make the
necessary adjustments to archive the desired product.
Adjust the overrun with the overrun controller (pos.7).
Adjust the viscosity with the viscosity controller (pos. 9).
The mix flow meter gives the mix flow rate expressed in litres per hour.