INSTRUCTION AND SERVICE PARTS MANUAL - FREEZER CS 800, s/n F0176-00 - ALFRED & CO
L7
9.3.2. OVERRUN SETTING & ADJUSTMENTS
For setting up or adjusting the desired overrun, please follow the
instructions given below.
Press the key "w" ( pos.7 ) one time. If you have inadvertently
pressed the key more than once, wait some seconds without
pressing any key and the tool will return to the starting point
The display "w" ( pos.2 ) will start lightening.
Press the key"< -"( pos.5 ) to select the digit to be changed, which will
still lighten when selected. Keep pressing key "< -" until you reach the
desired digit.
Press the key "+" ( pos.4 ) until the desired value is reached. If you
have gone beyond the desired value, you have to keep pressed the
key “+” until you reach once again the desired value.
To select another digit press key "< -" until you reach the desired
digit.
To change value press key "+".
When the desired overrun is all selected on the display "w" press key
">" (pos.6).
Display "x" ( pos.1 ) indicates instantaneously the quantity of air
metered ( litres/min ).
Display "w" indicates the set point.
Display "y" indicates the % of opening of the air mass flow meter.