INSTALLATION
BSS-134
CHAP.- 6
6.6 Safety devices
6.6.1 Mobile protections that can be opened
The mobile protections are provided with safety micro switch (see g.8 chap.6) that intervene at every
opening of the protection, activating the emergency stop.
Do not eliminate the safety micro switch function with electric or mechanical amendments.
NEVER USE THE MACHINE WITHOUT THE PROTECTIONS ACTIVE
THE CARRIER TRACKS MAY ALSO MOVE WHEN THE MOBILE PROTECTIONS ARE
OPENED
6.6.2 Emergency button
The machine is provided with a red mushroom-shaped button (see g.9 chap.6) that causes the
immediate stop.
This safety device must be used:
1. In case of imminent danger or mechanical accident;
2. When the machine is already stopped in phase and such state is to be maintained.
This button must be kept pressed in case of:
1. Maintenance interventions;
2. Operations requiring access and stay of the operator inside the dangerous area.
DO NOT USE THE EMERGENCY BUTTON FOR THE SERVICE STOPS BUT USE THE
STOP IN PHASE BUTTON
AFTER HAVING USED THE STOP IN PHASE BUTTON, THE SEALING UNIT REMAINS
POWERED ANYWAY.
6.6.3 Main switch
The handle of the main electric switch (see g.10 chap.6) is located on the front of the electric control
board, and can be locked using a padlock in the position of switch open.
The main switch must be disconnected in case of:
1. electric danger;
2. electric intervention on the machine or on the electric control board;
3. mechanical intervention on the machine.
The main switch must be locked using a padlock in the open position in case of:
1. cleaning or maintenance operations;
2. interventions on the machine in positions not directly visible from the electric control board.
Fig.9 chap.6
Fig.8 chap.6
Fig.10chap.6