4.5 INSTALLATION (BEERBLAST™ 7KPH / N2-GEN™ 7KPH)
The BeerBlast™ 7KPH / N2-GEN™ 7KPH Mixed Gas Dispense System can be installed for one or multiple CO2/ N2
blends. It is necessary to use caution when working with pressurized gas, making sure that all fittings and gas lines
are installed correctly. Always leak check every line before using the system.
Note: Line leaks will cause the BeerBlast™ 7KPH / N2-GEN™ 7KPH to run excessively, shortening its life.
In most systems, the BeerBlast™ 7KPH / N2-GEN™ 7KPH can supply two gas blends (of N2 and CO2) or a single
Nitrogen output for N2-GEN™ models. These lines can be split individually to provide the correct gas and/or
blended gas to all of the beverage lines. Use only quality beverage tubing and fittings for all connections. Keep in
mind the temperature and pressure requirements when selecting them.
Always install a valve (on/off) on each individual line. This will help with troubleshooting the system. Never detach
a line with pressure on it before closing the valve; this could cause damage to the equipment or bodily injury. Also
avoid depressurizing the keg at all costs; this will negatively affect the beer quality. Always shut off the valve and
remove the tap from the keg before changing or servicing the gas lines.
Two condensate drains for the generator are located on the bottom right of the cabinet. It is the responsibility of the
installer to plumb these drains to an area where standing water is trapped or a drain is located. Failure to do so can
cause a slipping hazard on the floor below the generator.
If your system requirements are more involved, please consult your sales representative or equipment installer for a