BeerBlast™ 7/14KPH & N2-GEN™ 7/14KPH O&M South-Tek Systems
26
6 SYSTEM MAINTENANCE
Whenever doing any maintenance to the system, make sure to power down the system. Remove the front cover to
gain access to the filters.
Annual Filter replacement kit part # FRP-001
Air Pre-Filter
The integrated Air Compressor has an air intake pre-filter. It is design to prevent particles from entering into the
compressor housing and damaging internal components. This filter needs to be replaced once per year or every
1000 hours, whichever comes first. To do so, remove the pre-compressor filter cap by twisting it clockwise. Remove
the old element and use a clean dry cloth to clean the filter bowl before installing the new element.