Chapter 2—Site Requirements Physical Requirements
February 2019 Site Preparation Guide—Spectra T950B Library
27
North America and Korea 200–240 VAC Power Cord The criteria for a
200-volt to 240-volt AC power cord in North America and Korea are as
follows:
International 200–240 VAC Power Cord The criteria for an international
200-volt to 240-volt AC power cord are as follows:
Supply-End Connector Types
The supply-end connector on the cord depends on the country where the
library will be installed. The following table shows the supply-end
connector types used in each country.
Parameter Specification
Power cordage SJT type, three-conductor, 14 AWG minimum
a
a. Power cord must comply with local electrical code.
Power input connectors Male: Connector must be of the proper type,
rating, and safety approval (see Supply-End
Connector Types on page 27).
Female: IEC 60320 C19
Parameter Specification
Power cordage Flexible, HAR (harmonized) type H05VV-F, three
conductor, cord with minimum conductor size of
1.7 square millimeters (0.0026350 square inches).
Power input connectors Male: Connector must be of the proper type,
rating, and safety approval for the intended
country (see Supply-End Connector Types on
page 27).
Female: IEC 60320 C19
Part
Number
Country of Use Plug Style Length Appearance
9594 North America,
Korea
NEMA L6-20P 14.8 ft (4.5 m)
7029 North America,
Korea
NEMA L6-30P 14.8 ft (4.5 m)
6807 Japan NEMA L6-20P 13.9 ft (4.24 m)
8665 United Kingdom,
Continental
Europe
IEC 60309 15 ft (4.6 m)