10
When Ordering Handsets and Spectralink
IP-DECT Server 200
Note:
It is recommended to plan your installation before ordering the Spectralink DECT Hand-
sets and Spectralink IP-DECT Server 200.
1. Allocate up to 4 - 6 handsets per Spectralink IP-DECT Server 200.
Note:
The unit provides a coverage radius of approximately 75 meter/245 feet and sup-
ports 6 simultaneous calls.
l If you want to use phone calls with all handsets all the time, allocate up to 6 handsets per
Spectralink IP-DECT Server 200.
l If you want to allow more users to use the system, you can allocate up to 12 handsets per
Spectralink IP-DECT Server 200 (up to any 6 handsets can be used at the same time).
2. Determine which handsets will be associated with each new (or existing) Spectralink IP-
DECT Server 200 on your virtual PBX. This will ensure you receive correct activation codes
that link your handset accounts with your Spectralink IP-DECT Server 200s when you order.
3. Within the same 30 meters/100-feet radius you can install up to 5 Spectralink IP-DECT Server
200s.
Example: 5 Spectralink IP-DECT Server 200s in the same 30 meters/100-feet radius support
up to 20 simultaneous calls, and up to 30 handsets in normal use.
Special Transmission Limitations and Requirements
l In multiple floor installations, transmission range across floors will likely be less than 75
meters/245-feet.
l Transmission range across heavy walls will likely be less than 75 meters/245-feet.
l Spectralink IP-DECT Server 200s are normally installed at or near the center of a 75
meters/245-feet radius cell.
At the Spectralink IP-DECT Server 200 installation point, either Ethernet with PoE or Eth-
ernet without PoE plus a nearby AC outlet and a PoE AC adaptor / PoE injector are required.
Spectralink IP-DECTServer 200 Deployment and Installation Guide