Pump
O󰀨
Pump
On Full
Pump On
Step 5
10
6
4
2
0
8
Pump O󰀨
Step 4
LEGEND
Blinking
On
O󰀨
PUMP SPEED SETTINGS
The pump has been set at the factory to run at full
speed when you first turn it on. At this setting, it
will pump at the rate of about 180 ml./min. This
may be adjusted in 10 steps. Step “1” is as slow as
the pump can safely run. When set at Step “10”,
the pump is running at full speed. During normal
operation, the lights will indicate the speed of the
pump. You may use the UP and DOWN buttons
to adjust the speed of the pump. When two
adjacent lights are lit, it indicates that the step is
the number between these two. (e.g. If the lights
next to 6 and 4 are both lit, the pump is running
at Step “5”.)
NOTE: The High Limit Sensor Tube acts as a safety
backup. It is on a separate circuit that will
operate even if the main processor and/or the
pump switch were to fail. If the water level
reaches the High Limit Sensor tube, the pump
will stop and all six lights will blink rapidly in
unison until the water level drops back below
the level of the High Limit Sensor tube. If the
processor is disabled, the pump will still turn
off but the lights will not blink.