Spectrasensors SS2100 User Manual

Spectrasensors SS2100
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SS2100 H
2
S Analyzer
Hardware Installation and Maintenance
Manual
Hardware Installation and Maintenance
Manual
P/N 4900002218 rev C
SS2100 H
2
S Analyzer
Hardware Installation
and Maintenance Manual

Table of Contents

Questions and Answers:

Spectrasensors SS2100 Specifications

General IconGeneral
Output Signal4-20 mA
CertificationsATEX, IECEx
Housing MaterialStainless Steel
Operating Humidity0-95% RH (non-condensing)
CommunicationRS-232/RS-485
Enclosure RatingIP66

Summary

Introduction to SS2100 H2S Analyzer

Manual Usage and Safety Guidelines

Information on how to use the manual, general warnings, safety labels, and symbols.

System Overview and Conventions

Covers manual conventions, company background, analyzer basics, and SCS.

Analyzer Technology and Function

Explains the SS2100 analyzer's technology, including TDLAS and WMS signal detection.

Getting Familiar with the Analyzer

Provides a visual introduction to the SS2100 analyzer's components and layout.

Installation of the SS2100 Analyzer

Preparation and Inspection

Details shipping contents, inspection procedures, and hardware/tools needed for installation.

Analyzer Mounting and Physical Setup

Covers mounting the analyzer, lifting, carrying, and selecting an installation location.

Electrical Power and Wiring

Step-by-step guide for connecting electrical power, including chassis, ground, and enclosure heater.

Signal, Alarm, and Gas Line Connections

Instructions for connecting output signals, alarms, gas lines, and conditioning the SCS tubing.

Analyzer Configuration and Calibration

Procedures for changing 4-20mA mode, calibrating the analog output, and adjusting zero/span.

Sample Conditioning System (SCS) Operations

SCS Overview and Installation Checks

Describes the SCS functions and outlines pre-operation installation checks.

SCS Startup and Operation Procedures

Detailed steps for preparing and starting up the SCS, including heaters, regulators, and flow.

SCS Shutdown and Isolation

Guidelines for safely shutting down and isolating the SCS for maintenance or storage.

System Purging and Shipment Preparation

Instructions for purging the system for shipment/relocation and details on heat trace bundles.

Appendix A: SS2100 Specifications

SS2100 Analyzer Technical Specifications

Comprehensive technical data on performance, application, and electrical parameters of the analyzer.

Replacement Parts Identification

A list of recommended spare parts with part numbers and quantities for the SS2100.

Appendix B: Maintenance and Troubleshooting

Common Operational Issues and Solutions

Addresses frequent problems like gas leaks, contamination, and environmental factors.

Safety Hazards and Personnel Precautions

Details potential risks, mitigation strategies, and safety precautions for personnel during servicing.

Component Maintenance and Replacement Guides

Step-by-step instructions for cleaning mirrors, replacing membrane separators, filters, and sensors.

SCS and Scrubber Maintenance Procedures

Guidance on routine SCS maintenance, status checks, and servicing the H2S scrubber.

Instrument Troubleshooting and Fault Diagnosis

A comprehensive table listing instrument problems and their corresponding solutions.

Service, Contact, and Logistics Management

Provides service contacts, return authorization, packing, storage, disclaimers, and warranty information.