SS2100 H
2
S Analyzer
Hardware Installation and Maintenance
Manual
Hardware Installation and Maintenance
Manual
P/N 4900002218 rev C
SS2100 H
2
S Analyzer
Hardware Installation
and Maintenance Manual

Table of Contents

Questions and Answers

  • N
    nramirezAug 12, 2025
    What to do if Spectrasensors SS2100 show a Laser Power Low Alarm fault?
    • O
      ohallAug 12, 2025
      If your Spectrasensors Measuring Instruments display a Laser Power Low Alarm fault, there are a couple of things to check: * First, power off the unit and inspect the optical head cables for any loose connections. * Second, try removing the connections to the inlet and outlet tubes to see if the power increases. This can help determine if stress on the tubes is the cause.
  • M
    michaelleeAug 15, 2025
    How to prevent contamination in Spectrasensors SS2100?
    • J
      janetdodsonAug 15, 2025
      To prevent contamination in your Spectrasensors Measuring Instruments, keep the gas sampling lines as free from contamination as possible. Regularly clean the sampling lines to maintain their cleanliness.
  • L
    lindacaseAug 19, 2025
    What to do if Spectrasensors Measuring Instruments are not getting enough flow to the sample cell?
    • V
      vgonzalezAug 19, 2025
      If your Spectrasensors Measuring Instruments are not getting enough flow to the sample cell, it could be due to contamination in the micro filter or membrane separator. Inspect both the micro filter and membrane separator for any contamination.
  • M
    megan65Aug 23, 2025
    What to do if Spectrasensors SS2100 Measuring Instruments show Pressure Low Alarm or Pressure High Alarm fault?
    • S
      Samantha SalazarAug 23, 2025
      If you are experiencing a Pressure Low Alarm or Pressure High Alarm fault with your Spectrasensors Measuring Instruments, there are a couple of things to investigate. First, verify that the actual pressure in the measurement cell is within the specified range. Second, check that the pressure/temperature cable on the bottom of the electronics enclosure is securely attached. Also, inspect the connector on the pressure transducer and the pressure connector on the backplane board.
  • C
    Carl JonesAug 27, 2025
    What to do if Spectrasensors SS2100 Measuring Instruments show Temp Low Alarm or Temp High Alarm fault?
    • J
      Joshua RobinsonAug 27, 2025
      If you encounter a Temp Low Alarm or Temp High Alarm fault with Spectrasensors Measuring Instruments, check the following: First, ensure that the actual temperature in the measurement cell is within the correct range. Second, for systems with a heated enclosure, confirm that the temperature in the measurement cell is within +/-5° C of the specified enclosure temperature.
  • K
    kellyrobertsAug 31, 2025
    Why is there contamination in Spectrasensors Measuring Instruments?
    • W
      wangdeborahAug 31, 2025
      Contamination in Spectrasensors Measuring Instruments can occur due to long exposure to high humidity or from existing contamination in the gas sampling lines. To address this, periodically clean the gas sampling lines and always strive to keep the sampling lines as free from contamination as possible.
  • A
    Andre LittleSep 4, 2025
    What to do if Spectrasensors Measuring Instruments have Laser Power Low Alrm fault?
    • B
      Brent FloresSep 4, 2025
      If your Spectrasensors Measuring Instruments are showing a 'Laser Power Low Alarm' fault, it might be due to liquid accumulation on the internal optics. Ensure that the filter included with most systems is installed ahead of the analyzer and is functioning correctly. Replace the filter if needed.
  • W
    William VasquezSep 7, 2025
    How to fix gas leaks in Spectrasensors SS2100 Measuring Instruments?
    • J
      james26Sep 7, 2025
      Gas leaks in Spectrasensors Measuring Instruments can be caused by outside air leaking into the sample supply line. It is recommended that you periodically leak test the supply lines, especially after the analyzer has been relocated, replaced, or returned from the factory for service and the supply lines have been reconnected.

Summary

Introduction to SS2100 H2 S Analyzer

Manual Usage and Safety Guidelines

Information on how to use the manual, general warnings, safety labels, and symbols.

System Overview and Conventions

Covers manual conventions, company background, analyzer basics, and SCS.

Analyzer Technology and Function

Explains the SS2100 analyzer's technology, including TDLAS and WMS signal detection.

Getting Familiar with the Analyzer

Provides a visual introduction to the SS2100 analyzer's components and layout.

Installation of the SS2100 Analyzer

Preparation and Inspection

Details shipping contents, inspection procedures, and hardware/tools needed for installation.

Analyzer Mounting and Physical Setup

Covers mounting the analyzer, lifting, carrying, and selecting an installation location.

Electrical Power and Wiring

Step-by-step guide for connecting electrical power, including chassis, ground, and enclosure heater.

Signal, Alarm, and Gas Line Connections

Instructions for connecting output signals, alarms, gas lines, and conditioning the SCS tubing.

Analyzer Configuration and Calibration

Procedures for changing 4-20mA mode, calibrating the analog output, and adjusting zero/span.

Sample Conditioning System (SCS) Operations

SCS Overview and Installation Checks

Describes the SCS functions and outlines pre-operation installation checks.

SCS Startup and Operation Procedures

Detailed steps for preparing and starting up the SCS, including heaters, regulators, and flow.

SCS Shutdown and Isolation

Guidelines for safely shutting down and isolating the SCS for maintenance or storage.

System Purging and Shipment Preparation

Instructions for purging the system for shipment/relocation and details on heat trace bundles.

Appendix A: SS2100 Specifications

SS2100 Analyzer Technical Specifications

Comprehensive technical data on performance, application, and electrical parameters of the analyzer.

Replacement Parts Identification

A list of recommended spare parts with part numbers and quantities for the SS2100.

Appendix B: Maintenance and Troubleshooting

Common Operational Issues and Solutions

Addresses frequent problems like gas leaks, contamination, and environmental factors.

Safety Hazards and Personnel Precautions

Details potential risks, mitigation strategies, and safety precautions for personnel during servicing.

Component Maintenance and Replacement Guides

Step-by-step instructions for cleaning mirrors, replacing membrane separators, filters, and sensors.

SCS and Scrubber Maintenance Procedures

Guidance on routine SCS maintenance, status checks, and servicing the H2S scrubber.

Instrument Troubleshooting and Fault Diagnosis

A comprehensive table listing instrument problems and their corresponding solutions.

Service, Contact, and Logistics Management

Provides service contacts, return authorization, packing, storage, disclaimers, and warranty information.

Spectrasensors SS2100 Specifications

General IconGeneral
Output Signal4-20 mA
CertificationsATEX, IECEx
Housing MaterialStainless Steel
Operating Humidity0-95% RH (non-condensing)
CommunicationRS-232/RS-485
Enclosure RatingIP66