SS2000
Gas Analyzer
Operator’s Manual
H
2
S in Natural Gas
(U.S.)

Table of Contents

Questions and Answers

  • K
    Kevin HendricksJul 31, 2025
    What to do if Spectrasensors Measuring Instruments show Laser Power too Low fault?
    • D
      Douglas BonillaAug 1, 2025
      If your Spectrasensors Measuring Instruments are showing a 'Laser Power too Low' fault, there are several potential causes and solutions: * A loose connection in the optical head cables could be the issue. Turn off the power and check the optical head cables. * Stressed inlet and outlet tubes can also trigger this fault. Inspect these tubes to ensure they are not under stress. * It could be due to a possible alignment problem or mirror contamination. In this case, contact a factory sales representative for service information. * Alternatively, press # 6 to capture diagnostic data and send the file to SpectraSensors for further analysis.
  • D
    Daniel LewisAug 5, 2025
    Why Spectrasensors SS2000 show Pressure too Low or Pressure too High fault?
    • S
      Shelly HullAug 5, 2025
      If your Spectrasensors Measuring Instruments display a 'Pressure too Low' or 'Pressure too High' fault, it could be due to these reasons: * The actual pressure in the measurement cell might be outside of the specified range. Verify that the pressure is within the correct range. * The pressure reading might be incorrect because of a loose connection or a faulty sensor. Ensure the pressure/temperature cable on the bottom of the electronics enclosure is securely tightened.
  • C
    Cheryl BrownAug 8, 2025
    What to do if Spectrasensors SS2000 Measuring Instruments show Temperature too Low or Temperature too High fault?
    • P
      perrycoreyAug 8, 2025
      If your Spectrasensors Measuring Instruments are showing a 'Temperature too Low' or 'Temperature too High' fault, consider the following: * The actual temperature in the measurement cell may be outside the specified range. Check that the temperature is within the correct range. * The temperature reading may be incorrect due to a loose connection or a faulty sensor. Make sure the pressure/temperature cable on the bottom of the electronics enclosure is tight.
  • J
    Joy RasmussenAug 13, 2025
    How to deal with contamination in Spectrasensors Measuring Instruments?
    • K
      Kimberly ScottAug 13, 2025
      Contamination in Spectrasensors Measuring Instruments can result from contamination in the gas sampling lines or long exposure to high humidity. To resolve this, it is recommended to periodically clean the gas sampling lines.
  • C
    Christopher HarrisAug 17, 2025
    Why is serial output providing no data from Spectrasensors SS2000?
    • G
      ghornAug 17, 2025
      If the serial output is providing no data from your Spectrasensors Measuring Instruments, it might be due to incorrect settings or faulty connections. Ensure that the computer COM port is set for 19200 baud, 8 data bits, 1 stop bit, no parity, and no flow control.
  • N
    Nathan JohnsonAug 21, 2025
    What to do if front panel display is not lit on Spectrasensors Measuring Instruments?
    • K
      Kathleen TorresAug 22, 2025
      If the front panel display of your Spectrasensors Measuring Instruments is not lit and no characters appear, it could be due to incorrect voltage input or faulty connections. Check for correct voltage on the terminal block input.
  • M
    Michelle ChristensenAug 26, 2025
    What to do if the reading seems to always be high by a fixed amount on Spectrasensors Measuring Instruments?
    • C
      Charles HarrisAug 27, 2025
      To address the issue of readings consistently appearing high by a fixed amount on your Spectrasensors Measuring Instruments, capture diagnostic data and send the file to SpectraSensors for analysis.

Summary

2 - INSTALLATION

Installing the Analyzer and Sample Conditioning System

Outlines the process for physically mounting the analyzer and its components.

Connecting Electrical Power to the Analyzer

Details the procedure for safely connecting the analyzer to its power source.

Connecting Electrical Power to the Optional Enclosure Heater

Explains how to connect power to the optional heated enclosure for the analyzer.

Connecting Electrical Power to an Analyzer with an Optional Type X Purge

Describes electrical power connection for analyzers with a Type X purge system.

Connecting the Input and Output Signals

Guides on connecting the analyzer's signal cables for data output and input.

Connecting the Gas Lines

Provides instructions for connecting sample inlet, return, and validation gas lines.

3 - OPERATING THE SS2000 SYSTEM

Powering Up the Analyzer

Outlines the steps to safely power on the SS2000 analyzer after installation.

Operating the Analyzer from the Keypad

Explains how to use the keypad interface to navigate and control analyzer functions.

Mode 2: (Set Parameter Mode)

Guides on accessing and changing measurement and control parameters for Channel A.

Scaling and Calibrating the Current Loop Signal

Provides steps for scaling and calibrating the 4-20 mA current loop output signal.

Alarms

Explains the types of alarms, their triggers, and associated messages on the analyzer.

Receiving Serial Data (RS-232 Output)

Details how to connect and receive data from the analyzer via RS-232 serial output.

Appendix A: Troubleshooting

Cleaning the Mirrors

Provides a detailed procedure for cleaning optical mirrors within the analyzer.

Instrument Problems

Lists common instrument issues and their corresponding troubleshooting responses.

Spectrasensors SS2000 Specifications

General IconGeneral
BrandSpectrasensors
ModelSS2000
CategoryMeasuring Instruments
LanguageEnglish