Installation - Device Parameters continued
DX FUNCTION SYSTEM DEFINITION DEFAULT
SETTING
D08
Frost Set point
5ºC to 17ºC
Required temperature for Frost
5ºC
temperature Protection and Holiday Mode
D09
Hour format
0 12
1
1 24
D10 N/A N/A N/A N/A
D11
Daylight Saving 0 OFF
1
Time (DST) 1 ON
D12
Heating Set point 5ºC to 35ºC Maximum temp that can
35ºC
limit be set for heating
D13
Cooling Set point 5ºC to 40ºC Maximum temp that can
5ºC
limit be set for Cooling
Floor sensor high
Output relay will be switched off
D14
limit temperature
6ºC to 45ºC when temp is reached for 27ºC
floor protection
Floor sensor Low
Output relay will be switched on
D15
limit temperature
6ºC to 45ºC when temp is reached for 10ºC
floor protection
Floor sensor limit
Output relay will be switched off
D16
for cooling
6ºC to 45ºC when temp is reached for 6ºC
floor protection
42
JGSTAT2 Installation Manual