EasyManua.ls Logo

Spellman EBM30N/TEG - User Manual

Spellman EBM30N/TEG
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2021 Spellman High Voltage Electronics Corporation
Tel : +44 (0)1798 877000
hvsales@spellmanhv.co.uk
Broomers Park, Pulborough,
W. Sussex, UK. RH20 2RY
Product:
EBM30N/TEG
Title:
Installation and User Guide
Document Number:
81773-4
Issue:
2
Date:
10/August/2021
Question and Answer IconNeed help?

Do you have a question about the Spellman EBM30N/TEG and is the answer not in the manual?

Summary

Safety

Servicing Safety

Safety precautions and guidelines for servicing the unit by qualified personnel.

Product Description

Rated Outputs

Specifies the voltage and current ratings for the various outputs of the EBM30N/TEG unit.

Bias Output and Bias Cancellation Supply

Explains the functionality and reference of the Bias Output and Bias Cancellation Supply.

Block Diagram

Presents a schematic overview of the unit and its interconnection with the SEM.

Environmental Conditions

Details the operating and storage temperature and humidity ranges for the unit.

Safety Guidelines

Meaning of Symbols

Defines the meaning of safety symbols used in the manual and on the equipment.

Installation of the HV Unit

Mechanical Installation

Provides instructions for physically mounting the unit within the end product.

Electrical Installation

Details the power requirements and electrical specifications for installation.

Connecting the Power Supply

Guides on connecting the unit to the power source and other components.

Control Connectors PL2 and PL3

Details the pinouts and functions of the analog and digital I/O connectors.

Input Power and Control Connectors Accessory Kit

Information on the accessory kit for low voltage connectors.

High Voltage Connector and Cables

Describes the high voltage connector type and available cable assemblies.

Scintillator Output and Cables

Details the bespoke receptacle and available cables for scintillator output.

PMT and Collector Outputs

Specifies the industry standard connectors used for PMT and Collector outputs.

Operation of the HV Unit

Control Signals

Explains the analogue and digital inputs used to control the unit's functions.

Monitor Signals

Details the analogue and digital outputs for monitoring the unit's status.

Protection Features

Outline Drawing

HV Cable Assembly

Scintillator Cable Assembly

Spellman EBM30N/TEG Specifications

General IconGeneral
Output Voltage0 to 30kV
Power Rating30W
Input Voltage100-240VAC
CoolingConvection
PolarityPositive or Negative
Frequency50/60Hz
Ripple0.1%
Efficiency85%
Ripple and Noise<0.1% p-p
Temperature Range0°C to +40°C Operating, -20°C to +70°C Storage