EasyManua.ls Logo

Spellman MONOBLOCK Series - Request Unit off Time

Default Icon
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101501-695 REV B 29
475 Wireless Boulevard • Hauppauge, New York 11788, USA • www.spellmanhv.com • T:+1 631.630.3000 • F:+1 631.435.1620
4.5.22 Request Unit Off Time
Description:
Returns the amount of time the power supply itself has been off since
the last seasoning has been performed.
Syntax:
<STX>OFTM;<CSUM><CR><LF>
Response:
<STX><ARG1>,<ARG2>;<CSUM><CR><LF>
Where:
ARG1 equals the hours and ARG2 equals the remaining hundredths of
hours that the supply has been off.
Example:
<STX>78,5;<CSUM><CR><LF> means that power supply has been
off for 78.05 hours.

Related product manuals