EasyManua.ls Logo

SPX DSV - Assembly of Feedback Units; Assembly of Manual Actuation; Double Seal Butterfly Valve; Dsv

SPX DSV
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.7 Attachment of turning actuator
- Place the adapter flange (10) on the upper housing and fasten it
with the inner hex. screws (9).
- Place the coupling (11) on the square of the actuating spindle
of the disc DSV (2).
- Place the turning actuator (16) on the adapter flange and tighten
it with the screws (12).
10.8 Assembly of feedback units (proximity switches)
- Valve position indication OPEN:
Installation of the feedback unit in the lower proximity
switch holder.
- Valve position indication CLOSED:
Installation of the feedback unit in the upper proximity
switch holder.
- Insert the proximity switch into the proximity switch holder until
stop and fasten it with the clamp union.
10.9 Assembly of manual actuation
- Place the handle on the square of the DSV disc and tighten it with
the fastening screws.
DSV disc and handle are in line.
10. Service Instructions
The reference numbers of the spare parts for the different valve
designs and sizes are included in the attached spare parts
drawings with corresponding lists.
Please indicate the following data to place an order for spare parts:
- number of required parts
- reference number
- designation.
subject to modifications
11. Spare Parts Lists
UK
13
Double Seal Butterfly Valve
DSV
Operating Manual: rev. 2
DSV-UK2.qxp / 10.2005
www.sks-online.com
www.sks-webshop.com