Coolant Change
Before replenishment, turn off the engine and
wait for until engine cool down.
1. Open the coolant surge tank cap slowly.
2. Remove the radiator drain plug to drain
the coolant completely.
3. Tighten the drain plug and fill the cool-
ant after mixing the antifreeze and wa-
ter properly through coolant surge tank
inlet.
4. Tighten the coolant surge tank cap and
start and run the engine until the upper
and lower radiator hoses become hot.
5. Check the coolant level again and add if
necessary.
CAUTION
Check for coolant leaks after chang-
ing coolant.
Service Interval and Capacity
Service interval Capacity
10.5 ~ 11.0 L
11.0 ~ 12.0 L
10.0 ~ 10.5 L
11.3 ~ 11.5 L
Change every 60,000 km.
And, inspect and replenish as
necessary.
Indirect Injection Diesel Engine
Direct Injection Diesel Engine
G23D Engine
G32D/G28D Engine