Fluids for Mobile Hydraulic
Tool Circuits
Recommended Fluid
s
ITEM U.S.A. METRIC
BRAND BIODEGRADABLE DESCRIPTION
The specification listed here will
provide good all season operation
if your circuit is of proper design
and normal maintenance is per-
formed.
(Periodic filter change,
draining of condensate, etc.
The fluids listed here work well
over a wide temperature range at
start-up, allow moisture to settle
out, and resist biological growth
likely in cool-operating hydraulic
Circuits.
These fluids are recommended by
Stanley Hydraulic Tools for use in
our tools. Other fluids that meet or
exceed the specifications of these
fluids may also be used.
P/N 15596 04/98 .5M
Hydraulic Recommendations
SPECIFICATIONS
RECOMMENDED FLUIDS
Viscosity (Fluid Thickness) 50 F 450 SSU Max 10 C 95 Centistokes Max.
Viscosity (Fluid Thickness) 100 F 130-225 SSU 38 C 27-42 Centistokes
Viscosity (Fluid Thickness) 140 F 85 SSE Min. 60 C 16.5 Centistokes Min.
Pour Point (Min. for cold startup) -10 F 23 C
Viscosity Index (ASTM D2220) 140 Minimum
Demulsibility (ASTM D1401) 30 Minutes Max.
Flash Point (ASTM D92) 340 F Min.
Rust Inhibition (ASTM D665 A&B) Pass
Oxidation (ASTM D943) 1000 Hours Min.
Pump Wear Test (ASTM D2882) 60 mg Max.
AMS-Oil No Hydraulic Fluid MN 150 SSU, 100 V.I.
Chevron No AW-MV-32
Exxon No “Univis J-26
Mobil No D.T.E. 13
Gulf No “Harmony AW-HVI-1 50-32
Shell No “Lo-Hydraul” 32
Sun No “Sunvis 805 MG
Texaco No “Rando” HD-AZ
Union No Unax AW-WR-32
Mobil Yes EAL 224H
Texaco Yes BioStar 32
Terresole Yes EnviroLogic 132
Shell Yes Naturelle HF-E-32
Pennzoil Yes Pennzsafe Sl200
°°
°°
°°
°°
°