EasyManua.ls Logo

Stanley Dura-Glide Series - Daily Safety Check Procedure; Electronic Controls Safety Check; Threshold System Safety Check; Doors and Frames Safety Check

Stanley Dura-Glide Series
10 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
DAILYSAFETYCHECK
ForYourCustomers’SafetyandYourOwnProtection
Perform This Safety Check on Each Automatic Sliding Door Each Day
And After Any Power Outage or Generator Test

SLIDEDOORSYSTEMSWITHELECTRONICCONTROLS
1. Check electronic sensor by walking toward the door opening fromseveralangles.
Thedoorshouldstartopeningwhenyouareaboutfivefeetfromthedoor.Thedoor
shouldslideopensmoothlyandstopwithoutimpact.Repeatontheothersideofthe
opening.
2. Step out of the sensor zone. After a brieftime delay, the door should slide closed
smoothlyandfullywithoutimpact.
3. Remain motionless at the side of the door with the door closed and cover the
doorwayholdingbeamwithyourhand.Thedoorshouldopenfully.
SLIDEDOORSYSTEMSWITHOVERHEADTHRESHOLDSAFETYSYSTEM
If your sliding door is equipped with an Overhead Threshold Safety System, check the
followingcomponentsdaily:
InsideandOutside ApproachActivationSensors‐Bothsensorsshouldbein
placeandshould operateasdescribedinsteps1and 2 underElectronicControls. For
“one way” traffic applications, one of the sensors will shut off when the door is fully
closed.Thesensorshouldturnonwhentheoppositesidesensoractivatesthissystem.
OverheadThresholdSafetySensor–TheOverheadThresholdSafetySensoris
mountedonthealuminumenclosuredirectlyabovethedooropening.Itsensespresence
inthethresholdzone.Thiszonecoversthefullwidthofthedooropeningand extends
approximately10”oneithersideofthethreshold.
Totestthesystem:
1. Walktowardsthedooropeningfromseveralangles.Thedoorshouldstartopening
whenyouareabout five feetfromthedoor.Thedoor should slideopensmoothly
andstopwithoutimpact.
2. Whenthedoorstartstoopen,theStan‐Guardsensorwillbeactivated.Walkintothe
thresholdareaandstop.AredindicatorlightontheStan‐Guardwillturnoffwhen
thecontrolsenses you.Stand inthethreshold zoneforseveral seconds.Thedoor
should remain open. Continue on through the opening and walk at least five feet
fromthedoor.Afterabriefdelay,thedoorshouldclose.
3. Turn and repeat the above zone tests by approaching the door from the opposite
direction.
DOORSANDFRAMES
1. Checkthedoorareafortrippingandslippinghazards.
2. Check all door panels for broken or cracked glass. There should be no bulletin
boards,literatureracks,merchandisedisplays,orotherattractionsinthedoorarea
wherepeoplecouldbehitbythedoor.
3. Doorshouldhavesafetydecalsproperlydisplayed.
FORSERVICE,CALLTOLLFREE
Ifyouhaveaproblemyoucannotcorrect,turnoffthedooroperatingequipmentandcallyourservice
1 888 DOOR 444