42
4. There is a problem in tool.
Remove cause of issue or contact
local service center
5. Trigger module is defective.
Replace motor & module assembly
or contact local service center
6. Smart function is turned off.
No NOK judgement if smart function
is turned off.
If needed, turn on smart function
Screen does not show process curve
or does not show correctly.
1. Smart function is turned off.
2. Rivet break load is small, it is
under 3,000N
Turn off smart function, if low break
load rivets are used
Tool does not count correctly
(does not count or counts even if it
does not set rivet).
1. Rivet break load is too small, it is
under 2,000N
Counter function cannot be used in
very low break load rivet.
2. Riveting cycle is too fast.
Pulled trigger before judgement.
Pull trigger for next riveting after
judgement.
4. Setting data are broken
Restore to factory settings
1. Smart function is turned on.
Rivets / Charge decreases, if smart
function is turned on. Turn on/off
smart function as needed.
2. Battery is not fully charged
Check battery charge level and
charge battery