41
Screen
Symptom Cause Remedy
1. Battery is not fully seated
Remove battery and re-insert. Reset
tool to home.
2. Battery is not fully charged
4. Battery pack has reached
operating temperature limit through
Remove battery & allow to cool.
Mount battery and reset tool to
Screen freezes in Stanley Engineered
Fastening Logo.
Remove battery and re-insert. Press
trigger to turn on.
2. Smart screen is defective
Contact a local service center
3. Trigger module is defective
Replace motor & module assembly
4. Setting data are broken
Restore to factory settings
Tool does not operate when trigger
switch
is pressed.
screen(Counter screen)
Change screen to home screen.
Touch “Back home” icon to be back
Even if touch screen, screen doesn
not respond or screen becomes all
Remove battery and re-insert. Press
trigger to turn on.
If does not revert, contact local
3. Alarm message is shown with
beep sound.
Reset alarm refering to the related
pages.
4. Setting data are broken
Restore to factory settings
5. Radio communication error
Even if restores to factory settings, if
does not revert, contact local
Tool shows NOK, even if it sets rivet
correctly.
1. Judgement range setting is not
correct
Set judgement range correctly
2. Judgement range setting is too
small
3. Not fasten 5 rivets in average
mode
Fasten 5 rivets, if it has an error, do
it again
Do maintenane around jaw area
5. Tool is not at home position
6. There is a problem in tool.
Remove cause of issue or contact
local service center
7. Trigger module is defective.
Replace motor & module assembly
or contact local service center
Tool does not show NOK, even if it
sets incorrect rivet
1. Judgement range setting is not
correct
Set judgement range correctly
2. Judgement range setting is too
largel
3. Not fasten 5 rivets in average
mode
Fasten 5 rivets, if it has an error, do
it again