9
E
Turning Off the Tool
The tool can be turned off in either of these ways:
• Press and hold
for 10 seconds. When you release after 10 seconds, the tool will turn off.
• If you do not use the tool for 90 seconds, it will automatically turn off.
Warranty
STANLEY warrants this product for a period of (2) years against deficiencies in material and workmanship. This LIMITED
WARRANTY does not cover products that are improperly used, abused, altered, or repaired. Please call 866-786-5924 for more
information or return instructions. Unless otherwise noted, STANLEY will repair without cost, any STANLEY product found to be
defective, including parts and labor charges, or at STANLEY’s option, will replace such tools or refund the purchase price, less
the amount for depreciation, in exchange for the defective tool. THIS LIMITED WARRANTY EXCLUDES ALL INCIDENTAL OR
CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so these limitations may not apply to you. This TWO YEAR LIMITED WARRANTY gives you specific legal rights that may vary
from state to state. In addition to the warranty, STANLEY Lasers are covered by: 30-Day Money Back Guarantee. If you are not
completely satisfied with the performance of your STANLEY Laser for any reason, you can return it within 30 days from the date of
purchase with a receipt for a full refund.
IMPORTANT NOTE: The customer is responsible for the correct use and care of the instrument. Moreover, the customer is
completely responsible for periodically checking the accuracy of the laser unit, and therefore for the calibration of the instrument.
Calibration and care are not covered by warranty.
Error Codes
If INFO appears on the display window with a Code number, perform the corresponding Corrective Action.
Code Description Corrective Action
101 Received Signal Too Weak,
Measuring Time Too Long
Use the target plate or change the target surface.
102 Received Signal Too High Target is too reective. Use the target plate or change the
target surface.
201 Too Much Background Light Reduce the background light on the target area.
202 Laser Beam Interrupted Remove the obstacle and repeat the measurement.
203 Insufcient Power Replace the batteries.
301 Temperature Too High Allow the device to cool down to a temperature within the
specied Operating Temperature Range.
302 Temperature Too Low Allow the device to warm up to a temperature within the
specied Operating Temperature Range.
401 Hardware Error Switch the device on/off several times. If the error still occurs,
return the defective device to the Service Center or distributor.