STANLEY TLM65
6
EN
Technical Data
* The typical measurement uncertainty of ± 3 mm is 
valid for measurements on white, diffusive, reflective 
targets up to 5 m at low ambient light and moderate 
temperatures. For distances greater than 5 m,  the 
measurement uncertainty could increase additionally 
by 0.1 mm/m.  In unfavourable conditions (such as 
bright sunlight, targets with poor reflectivity, or high or 
low temperatures)  the measurement uncertainty 
could further increase up to ± 4 mm for distances 
below 5 m and additionally by roughly 0.15 mm/m for 
distances greater than 5 m. 
Message Codes
If the message Error does not disappear 
after switching on the device repeatedly, 
contact the dealer.
If the message InFo appears with a 
number, press the Clear button and 
observe the following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents 
or solvents.
Disposal
CAUTION
Flat batteries must not be disposed of with 
household waste. Care for the environ-
ment and take them to the collection points 
provided in accordance with national or 
local regulations.
The product must not be disposed with 
household waste.
Dispose of the product appropri-
ately in accordance with the 
national regulations in force in your 
country.
Adhere to the national and country specific 
regulations.
Product specific treatment and waste 
management can be downloaded from our 
homepage.
Warranty
The Stanley TLM has a two-year warranty.
For further information on this, contact 
your dealer.
Subject to change (drawings, descriptions 
and technical data).
General
Range 21 cm - 20 m
8’’ - 65’
Measuring accuracy* ± 3 mm
± 1/8’’
Smallest unit displayed 1 mm
1/16 in
Laser class 2
Laser type 635 nm, < 1 mW
Autom. power switch-off after 120 s
Continuous measuring yes
Area / Volume yes
Dimension (H x D x W) 110 x 44 x 21 mm
4.33 x 1.73 x 0.83 in
Battery durability (2 x AAA) up to 3000 measure-
ments
Weight 
(without batteries)
71 g / 2.5 oz
Temperature range:
-Storage
-Operation
-25 to 70 °C
-13 to 158 °F
0 to 40 °C
32 to 104 °F
No. Cause Correction
252 Temperature too high Let device cool 
down.
253 Temperature too low Warm device up.
255 Received signal too 
weak, measuring time 
too long
Change target 
surface (e.g. white 
paper).
256 Received signal too 
high
Change target 
surface (e.g. white 
paper).
257 Too much background 
light
Shadow target area.
258 Measurement outside 
of measuring range
Correct range.
260 Laser beam inter-
rupted
Repeat measure-
ment.