798 Series
IP67 Electronic Caliper
USER'S GUIDE
Question and Answer IconNeed help?

Do you have a question about the Starrett 798 Series and is the answer not in the manual?

Starrett 798 Series Specifications

General IconGeneral
BrandStarrett
Model798 Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

INTRODUCTION

BATTERY INSTALLATION

OPERATING INSTRUCTIONS

Automatic OFF

The caliper display turns off after 30 minutes of inactivity and can be reactivated by movement or button press.

In/mm Button

Allows switching between inch and millimeter modes or acts as a send button when output is connected.

Zero On/Off Button

Activates display, zeros the tool, or shuts off the display with different press durations.

Output (798B only)

798B models support data transmission via cable or wireless interface.

Low Battery Indication

A battery symbol indicates low battery, requiring replacement as per instructions.

SPECIFICATIONS

Dust/ Water Protection

IP67 rating indicates complete protection against dust and submersion in water up to 1 meter for 30 minutes.

Ranges

Calipers are available in 6" (150mm), 8" (200mm), and 12" (300mm) measurement ranges.

Resolution

The measurement resolution is 0.0005 inches or 0.01mm.

Accuracy

Accuracy specifications are ±0.001"/0.02mm (≤4") and ±0.001"/0.03mm (>4"), meeting DIN 862.

Operational Temp.

The operating temperature range is +41° to +104°F (+5° to +40°C).

Data Output

798B models feature patented non-contact USB cable data output.

Battery

Uses a Lithium Coin Cell 3V, CR2032 or equivalent.

Battery Life

Provides over 3500 hours of continuous use.

Auto Shutdown

The instrument automatically shuts down after 30 minutes of non-use.