Troubleshooting
Problem Possible cause Remedy
Air bubbles escape from the
injection nozzle or the pump emits
unusual noises.
The pump is sucking in air. Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
with more water if necessary until the
pool water covers the suction line
connection approx. 2.5 - 5cm (1 to 2 in).
The water level in the pool is too
low.
Raise the water level in the pool.
The suction line is out of place
or clogged.
Clean the pressure line.
The pump is not running. The pump has no power. Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
The external timer is set. Check the running times on the external
timer.
The pump is defective. Contact customer service.
If the problem cannot be solved, contact the customer service listed on the last page.
Technical data
Model: CPS 40-2 Flow rate: max. 4,500 l/h (36.3 GPM)
Item number: 040955 Delivery head: max. 6.5 m (21 ft.)
Pump function principle: not self-priming Pool volume (water
content):
max. 19,000 l (10,000 gal)
Prefilter: - - - - - Water temperature: max. 35 °C (95 °F)
Timer: - - - - - Connection diameter: Ø 32/38 mm
Battery for timer: - - - - - Safety class: IPX5
Power supply: 220-240 V~, 50 Hz Insulation class: F
Output: max. 200 W Sound pressure level ****:<70 dB(A)
**** Emission sound level comparable to a large household appliance
22