29
USA and Canada 800.683.2378, International 904.641.1666 Econ FP
HAZARDOUS VOLTAGE:
DISCONNECT power before service. Electrical service should be performed by trained
personnel only.
PROBLEM POSSIBLE CAUSE SOLUTION
Noise is excessively loud Lubrication is insufficient Grease gears and gear posts
Gears or gear posts are worn Inspect/replace gears and gear posts
Drive assembly does not work Electrical supply is faulty Check supply voltage circuit
DC motor is damaged Replace drive assembly
Power cord or power supply Replace drive assembly
is damaged
Drive assembly runs; Worn or damaged gears Replace gears as needed
output shaft does not
Phenolic gear is stripping Gear posts worn Replace gear posts and phenolic gear
Rusted helical gear Buff off helical gear and replace phenolic gear
Insufficient lubrication Replace phenolic gear and lubricate
with AquaShield
™
Output shaft does not turn Worn or damaged roller assembly Replace roller assembly and cycle power to reset
Worn or damaged gears Replace gears as needed and cycle power to reset
Damaged circuit board Replace drive assembly
TROUBLESHOOTING – DRIVE ASSEMBLY