    Kenneth JohnstonAug 17, 2025
    What to do if my Stertil-KONI Lifting Systems has no battery power?
    • C
      Cassandra CarrollAug 17, 2025
      If your Stertil-KONI Lifting Systems has no battery power, try these solutions: * Charge the batteries using the provided mains cable, avoiding external booster chargers. It is also recommended to have the batteries checked by a specialist. * Check the main fuse located above the batteries. * Ensure the main switch is set to the ON position.
  • K
    kimberlybradfordAug 20, 2025
    What to do if my Stertil-KONI Lifting Systems column lift cannot be raised?
    • T
      Tammy SmithAug 20, 2025
      If your Stertil-KONI column lift cannot be raised, consider the following: * Check the main fuse above the batteries and have the batteries inspected by a battery specialist if there's no battery power. * If the oil level is too low but the motor is running, top up the oil. * If air is present in the hydraulic pump (possible after the tank has been empty), select [SINGLE] operation and press the [UP] button until the column lift rises, but no more than 1 minute.
  • D
    Destiny HansenAug 26, 2025
    What to do if my Stertil-KONI Lifting Systems has no control voltage?
    • C
      cody70Aug 26, 2025
      If your Stertil-KONI lifting system has no control voltage: * Set the main switch to ON. * The controller has multi-fuse circuit breakers. After they have cooled down, they switch back on again automatically. If the fault occurs again, contact technical services. * Follow the normal operation procedures as described in the Operation Manual. If the fault occurs again, contact technical services.
  • F
    fbryantAug 28, 2025
    What to do if my Stertil-KONI Lifting Systems battery is flat and movements are impossible?
    • J
      Jennifer WilsonAug 28, 2025
      If your Stertil-KONI Lifting Systems has a flat battery and you can't perform any movements: * Set the system to charging if it happens after more than 15 movements on a single battery charge. * Charge the batteries of the column if one of the columns was not charged in time.
  • M
    Mark SmithAug 30, 2025
    What to do if my stertil-KONI ST 1085-VFWA Lifting Systems lowering motion stops and the lower stop limit message appears?
    • M
      Mrs. Caitlin RoseAug 31, 2025
      If the lowering motion stops and the message 'The lower stop limit has been reached' appears on the screen of your Stertil-KONI Lifting Systems, raise the columns approximately 4" and remove any obstacles. The column lifts can now be lowered further. Do not forget to press the [UNLOCK] button first.
  • Z
    Zoe SchroederSep 2, 2025
    Why does my stertil-KONI ST 1085-VFWA raising motion stop and show a maximum height reached message?
    • M
      Margaret PhamSep 3, 2025
      If the raising motion stops and the message 'Maximum programmed height reached' appears on the screen of your Stertil-KONI Lifting Systems, it means one of the columns has reached its highest position. In this case, lower the columns.
  • K
    Kyle LeachSep 5, 2025
    What happens if foot guard limit has been reached in stertil-KONI ST 1085-VFWA Lifting Systems?
    • A
      Andrew AguilarSep 5, 2025
      If the foot guard limit has been reached on your Stertil-KONI Lifting Systems, lower the columns to reach ground level.
  • F
    Faith ParkerSep 8, 2025
    What to do if emergency switch is pressed on Stertil-KONI Lifting Systems?
    • J
      Jessica LambSep 8, 2025
      If the emergency switch is pressed on your Stertil-KONI Lifting Systems, it likely indicates a dangerous situation. Release the switch only when it is safe to do so.
  • S
    Samantha WelchSep 12, 2025
    What to do if Service Mode (PCB Main button pressed) is active on Stertil-KONI Lifting Systems?
    • W
      willierobertsSep 12, 2025
      If the Service Mode is active on your Stertil-KONI Lifting Systems (PCB Main button pressed), release the buttons on the control board and start up again.
  • B
    Barbara LeblancSep 13, 2025
    What to do if stertil-KONI ST 1085-VFWA shows error in another column?
    • W
      websterchristopherSep 13, 2025
      If your Stertil-KONI Lifting Systems shows an error in another column, check other columns for system errors.

Summary

2 SAFETY

2.2 Hazards

Covers potential hazards including electrical, mechanical, and fall risks.

2.3 General safety instructions

Details importance of safety, procedures, warnings, personnel, and instructions.

2.4 Safety features

Describes safety mechanisms like emergency stop, and safety signs.

2.5 Lock-out; Tag-out

Explains procedures to prevent energy application during servicing.

3 DESCRIPTION

3.1 Technical specifications

Lists key technical data like lifting capacity, power, and dimensions.

3.3 Lifting capacity

Specifies the maximum load the lift can handle and its safety features.

3.4 Lifting system

Describes the electrically driven hydraulic column lift system components.

3.5 Control system

Details how the system ensures synchronized lifting and height control.

3.6 Hydraulic power unit

Describes the components of the hydraulic power unit.

3.7 Column, lifting cylinder and guide block

Explains the main structural parts of the mobile column lift.

3.8 Control box

Details the functions of the control panel and emergency stop.

3.9 Pallet lifting mechanism

Describes the mechanism used for relocating the column lift.

3.11 Locking feature

Describes the mechanical safeguard that prevents falling if hydraulic pressure fails.

4 INSTALLATION

4.1 Unpacking and Setup

Provides step-by-step instructions for unpacking and initial setup.

5 INSPECTION AND MAINTENANCE

5.2 When You Carry Out Maintenance

Covers preparations, safety, waste disposal, and record-keeping for maintenance.

5.3 Monthly Maintenance

Lists essential monthly inspection and lubrication tasks.

5.4 Annual Maintenance by the Technical Service

Outlines requirements for yearly inspections by authorized technicians.

5.5 Regular Preventive Maintenance Procedures

Details lubrication, hydraulic oil replacement, and safety feature checks.

5.8 Settings Screen

Covers user settings, shop configuration, and user administration.

5.9 Special Procedures

Details procedures for managing users, setting the clock, and height limits.

5.10 Corrective Maintenance

Outlines safety, knowledge, repair requests, communication, and parts for repairs.

5.12 Corrective Maintenance Procedures

Provides steps for removing/installing cylinders and adjusting mechanisms.

5.13 List of Parts

Explains the structure and titles of the parts list.

5.14 Replacement Parts

Guides on ordering replacement parts with necessary information.

6 TROUBLESHOOTING

6.1 General

Provides general advice for diagnosing and resolving faults.

6.2 Messages

Explains system messages displayed during operation, like lowering stops.

6.3 Information Messages

Lists system messages, their causes, and solutions for bringing the system back to normal status.