OPERATION
Settings
www.stiebel-eltron-usa.com CON Premium | 7
ENGLISH
Display Description
Switch “Window open detection” function on and off
If the Pro4 time program (120minute timer) is activated, the
“Window open detection” function is disabled.
Select time program (Pro1, Pro2, Pro3, Pro4, off)
Switch “Adaptive start” function on and off
If the Pro4 time program (120minute timer) is activated, the
“Adaptive start” function is disabled.
To change the setting of a menu item, call the relevant menu item
up using “+” and “–”. Press “OK”.
As soon as the “Editable parameter” symbol appears, you can
change the setting of the menu item with “+” and “–”. Press “OK”
to save the setting.
To exit the standard menu, press “Menu”. The standard display
appears.
6.3.1 120-minute short-time timer (Pro4)
With the 120-minute short-time timer, you can activate comfort
mode for a selected time of up to 120minutes. During this selected
time, the unit heats to the set comfort temperature. After this, the
heater operates in night mode.
f If you wish to use the 120-minute short-time timer, select
time programPro4 from the standard menu.
D0000075531
The standard display shows the selected time in minutes as well as
the “Editable parameter” symbol. Using the “+” and “-” buttons,
you can select any length of time from 10 – 120minutes.
To activate the short-time timer, press “OK”. The heater switches
to comfort mode until the end of the selected time. The minute
display flashes during this period.
If you wish to stop the short-time timer, press and hold “OK” for
longer than 3seconds.
At the end of the selected time, the heater automatically reverts
to night mode.
6.4 Configuration menu
Display Description
I1-I2 Actual values
Pro1-Pro3 Time programs
P1-P5 Parameter
In the configuration menu, you can call up actual values, set time
programs and adjust parameters.
To access the configuration menu, press and hold “Menu”. After
approx.3seconds, actual valueI1 is displayed.
Use “+” and “–” to switch between the individual actual values,
time programs, and parameters.
To exit the configuration menu, press “Menu”. The standard dis-
play appears.
6.4.1 Actual values
The following actual values can be called up:
Display Description Unit
I1 Actual room temperature [°C] | [°F]
I2 Relative heating time
(The counter can be reset via parameter P5.)
[h]
Note
The counter for relative heating time(I2) counts in com-
plete hours how long the heater heats for. When the
heater is switched off, any heating phase of less than
60minutes is not recorded.
6.4.2 Time programs
Four time programs are available. Time programs Pro1 and Pro2
are pre-configured at the factory. Time program Pro3 can be set
according to your individual requirements. Time program Pro4 is
a 120-minute short timer.
Display Description
Pro1 Time program “Daily”
- Repeated: Monday to Sunday
Pro2 Time program “Weekdays”
- Repeated: Monday to Friday
Pro3 Time program “User defined”
- up to 14comfort phases, freely configurable
Pro4 120-minute short time program “Quick heat”
- User selects up to 120 minutes of comfort heating.
Note
To use a time program, select the required time pro-
gram from the standard menu (See section 6.3, “Stan-
dard menu”, pg. 6). To use Pro4, the 120-minute short
timer, see section 6.3.1, “120-minute short-time timer
(Pro4)”, pg. 7.
Note
Ensure the day of the week and the time are set correctly
when setting the time programs.
Note
The following applies to all time programs (Pro1, Pro2,
Pro3):
If the end time is later than 23:59h, the end time will
automatically be moved to the next day of the week. The
comfort phase is maintained past midnight and will end
on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with time
programsPro1 and Pro2. During this time period, the heater heats
to the set comfort temperature. Outside this specified time period,
the heater operates in night mode. This results in a comfort phase