OPERATION
Cleaning, care and maintenance
8 | CON Premium www.stiebel-eltron-usa.com
and a night phase, which are repeated daily(Pro1) or on every
working day (Pro2).
Theses phases are factory-set as follows:
- 08:00am - 10:00pm: Comfort mode
- 10:00pm - 08:00am: Night mode
Note
When time programPro2 is enabled, the heater operates
during weekends exclusively in night mode.
To adapt time programsPro1 and Pro2 according to your needs,
proceed as follows:
f In the configuration menu, use “+” and “–” to call up the re-
quired time program.
f Press “OK”.
The start time for comfort mode is displayed.
f Use “+” and “–” to set the required start time.
f Press “OK”.
The end time for comfort mode is displayed.
f Use “+” and “–” to set the required end time.
f Press “OK” to save.
Time program Pro3
You can use time programPro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time programPro3, proceed as
follows:
f In the configuration menu, use “+” and “–” to call up time
programPro3.
f Press “OK”.
The display shows “3---”.
f Press “OK”.
A day of the week or a group of days is displayed.
f Use “+” and “–” to select the required day or group of days.
f Press “OK”.
The start time for comfort mode is displayed.
f Use “+” and “–” to set the required start time.
f Press “OK”.
The end time for comfort mode is displayed.
f Use “+” and “–” to set the required end time.
f Press “OK”.
Comfort phase “3-01” has been configured.
f To configure a further comfort phase, use “+” and “–” in time
programPro3 to select display“3---. Proceed as described
above.
Note
To reset the selected comfort phases, activate parame-
terP4.
f Please note that activating parameterP4 resets all
time programs (Pro1, Pro2, Pro3) to the factory set-
ting.
6.4.3 Parameters
You can call up the following parameters:
Display Description Options
P1 Room temperature offset ±3°C | ±5°F
P2 Time format 12h | 24h
P3 Temperature display units °C | °F
P4 Reset the time programs (Pro1, Pro2, Pro3). on | off
P5 Reset relative heating time on | off
To change the value of a parameter, use “+” and “–” to call up the
relevant parameter. Press “OK”.
As soon as the “Editable parameter” symbol appears, you can
change the parameter value with “+” and “. Press “OK” to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a differ-
ence between displayed actual temperatureI1 and the room tem-
perature you measure. To compensate for this difference, a room
temperature offset of ±5 °F (±3 °C) can be set via parameterP1.
Example: The heater indicates I1=70 °F (21.0 °C). You have mea-
sured a room temperature of 68 °F (20.0 °C). There is a difference
of 2 °F (1.0 °C).
f To compensate for the difference, select an offset of P1=-2.0
(-1.0).
P2: Time format
ParameterP2 allows you to specify whether the time is displayed
in 12hour or 24hour format.
P3: Temperature display units
ParameterP3 is used to specify whether the room temperature is
displayed in degrees Fahrenheit [°F] or Centigrade [°C].
P4: Reset time programs
Activating parameterP4 resets all time programs (Pro1, Pro2,
Pro3) to the factory setting.
P5: Reset relative heating time
Activating parameterP5 resets the counter for relative heating
time (I2).
7. Cleaning, care and maintenance
The heater contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the heater.
- If a pale brownish discoloration appears on the heater cas-
ing, wipe it off as soon as possible with a damp cloth.
- Clean the heater when cold with ordinary cleaning products.
Avoid abrasive or corrosive cleaning products.