Installing the appliance
D0000073842
321
1 Grommets
2 Flat gasket
3 Strainer with sealed edge
Mark out the 2holes for drilling with reference to the appli-
ance back panel.
Fit the grommets in the appliance back panel from the front.
Drill the holes and secure the appliance using suitable fixing
materials (screws and rawl plugs are not part of the standard
delivery): Countersunk screw, Ø4.5mm, max. diameter of
screw-head 9mm.
Note
Install the appliance flush to the wall. If necessary,
additionally secure the appliance at the 2 lower at-
tachment points.
Remove the transport protection plugs from the water con-
nection pipes.
Secure the DHW connection pipe with a flat gasket and the
cold water inlet line with the sealed-edge strainer (from the
accessories) to the twin connectors.
12.6 Operation with preheated water
You can limit the maximum inlet temperature by installing a cen-
tral thermostatic valve.
13. Service information
Connection overview/ component overview
D0000082950
1
2
3
4
1 Flow meter
2 High limit safety cut-out, automatic reset
3 Pin strip for connected load
4 Diagnostic traffic lights