INSTALLATION
Safety
6 | DCE-S Plus www.stiebel-eltron.com
INSTALLATION
5. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
5.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
!
Material losses
Observe the maximum inlet temperature. Higher tem-
peratures may damage the appliance. You can limit the
maximum inlet temperature by installing a central ther-
mostatic valve.
WARNING Electrocution
This appliance contains capacitors which are discharged
when disconnected from the power supply. The capacitor
discharge voltage may briefly exceed60VDC.
5.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
- Protection rating IP25 (hose-proof) is guaranteed only if
appropriate cable grommets and O-rings are fitted on the
45°twin connectors.
- The electrical resistivity of the water must not fall below that
stated on the type plate. In a linked water network, take into
consideration the lowest electrical resistivity of the water.
Your water supply utility will advise you of the electrical re-
sistivity or conductivity of the water in your area.
6. Appliance description
6.1 Standard delivery
The following are delivered with the appliance:
- 2 x 45° twin connectors
- 2 flat gaskets
- 2 O-rings
- Cable grommet
- Strainer
- Flow limiter
- Jumper for anti-scalding protection, attached
- Jumper for output changeover, attached
6.2 Accessories
Taps
- MEKD mono lever kitchen pressure tap
- MEBD mono lever bath pressure tap
Installation kit for water installation on unfinished walls
The following accessories are required for water installation on
unfinished walls:
- 2 x grommets to seal the apertures in the appliance back
panel.
- Strainer with sealed edge for installation on the 45°twin
connector.
- Flat gasket
Central thermostatic valve (ZTA3/4)
Use the thermostatic valve for central premixing, for example
when operating an instantaneous water heater with preheated
water. For use in shower operation, the valve must be set to a
maximum of 55°C.
7. Preparation
7.1 Installation site
!
Material losses
Install the appliance in a room that is free from the risk
of frost.
Always install the appliance vertically and near the draw-off
point.
The appliance is suitable for undersink and oversink installation.
Undersink installation
D0000073616
1
2
1 Cold water inlet
2 DHW outlet
Oversink installation
12
D0000073617
1 Cold water inlet
2 DHW outlet