EasyManua.ls Logo

STIEBEL ELTRON DCE-S 6/8 Plus - Commissioning; Internal Anti-Scalding Protection via Jumper Slot; Changing the Connected Load via the Jumper Slot; Initial Start-up

STIEBEL ELTRON DCE-S 6/8 Plus
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Commissioning
ENGLISH
www.stiebel-eltron.com DCE-S Plus | 9
9. Commissioning
9.1 Internal anti-scalding protection via jumper
slot
43°C | 109°F
50°C | 122°F
55°C | 131°F
60°C | 140°F
D0000073624
Jumper position Description
43°C | 109°F Forexample in nurseries, hospitals, etc.
50°C | 122°F
55°C | 131°F Max. for shower operation
60°C | 140°F Factory setting
No jumper Limit 43°C | 109°F
Install the jumper in the required position on the "Tmax" pin
strip.
CAUTION Burns
If the appliance is supplied with preheated water, the
internal anti-scalding protection and the user-adjustable
temperature limit may be exceeded.
In such cases, limit the temperature with an upstream
central thermostatic valve (ZTA3/4).
9.2 Changing the connected load via the jumper
slot
If you select a connected load other than the factory setting for
the appliance, you will need to reposition the jumper.
1
2
D0000082938
Install the jumper in the required position on the "Pmax" pin
strip.
Jumper position Connected load
DCE-S 6/8 Plus
Connected load
DCE-S 10/12 Plus
1 @ 220V 6.0kW 10.0kW
@ 230V 6.6kW 11.0kW
@ 240V 7.2kW 12.0kW
2
@ 220V 8.0kW 12.0kW
@ 230V 8.7kW 13.1kW
@ 240V 9.6kW 14.3kW
No jumper
@ 220V 6.0kW 10.0kW
@ 230V 6.6kW 11.0kW
@ 240V 7.2kW 12.0kW
9.3 Initial start-up
Tick the selected connected load on the type plate. Use a
ballpoint pen to do this.
≥ 60 s
D0000053277
Open and close all connected draw-off valves several times,
until all air has been purged from the pipework and the
appliance.
Carry out a tightness check.
D0000073622
Activate the safety switch by firmly pressing the reset button
(the appliance is delivered with the safety switch disabled).
D0000082937
Insert the plug of the programming unit connecting cable at
the PCB.
Note
It is essential to plug the connecting cable for the pro-
gramming unit into the PCB before switching on the
power. Otherwise, the programming unit will not func-
tion.

Table of Contents

Other manuals for STIEBEL ELTRON DCE-S 6/8 Plus

Related product manuals