INSTALLATION
Maintenance
18 | DCE-X Premium www.stiebel-eltron.com
16. Maintenance
WARNING Electrocution
Before performing any work on the appliance, discon-
nect all poles from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
Close the shut-off valve in the cold water inlet line.
Open all draw-off valves.
Undo the water connections on the appliance.
Store the dismantled appliance free from the risk of frost, as
water residues remaining inside the appliance can freeze and
cause damage.
Cleaning the strainer
If the strainer in the threaded cold water fitting is dirty, clean it.
Close the shut-off valve in the cold water inlet line before remov-
ing, cleaning and refitting the strainer.
17. Specification
17.1 Dimensions and connections
372
358
343
14
97
217
140
175
100
c01c06
35
32
109
b02
380
D0000073693
DCE-X
Premium
b02 Entry for electrical cables I Finished walls
c01 Cold water inlet Male thread G 1/2 A
c06 DHW outlet Male thread G 1/2 A
Alternative connection options
100
c01c06
b02
72
330
b02
b02
69
35
336
b02
b03
30
61
15
b03
D0000073720
DCE-X
Premium
b02 Entry for electrical cables I Finished walls
b03 Entry for electrical cables II Unfinished walls
c01 Cold water inlet Male thread G 1/2 A
c06 DHW outlet Male thread G 1/2 A
17.2 Wiring diagram
DCE-X Premium
L L
2/GRD ~ 220 - 240 V
L N
1/N/PE ~ 220 - 240V
N
L
L
L
D0000077991
1
3
4
2
1 Power PCB with integral safety switch
2 Bare wire heating system
3 High limit safety cut-out
4 Mains terminal

Table of Contents