OPERATION
Settings and displays
6 | DCE-X Premium www.stiebel-eltron.com
4.3 Setting the temperature
D0000073619
2
1
1 Set temperature selector (no end-stop): OFF, 20 - 60°C
2 To call up/assign preferred temperatures
Settings
Setting Step Setting Step
20°C ... 60°C 0.5°C 68°F ... 140°F 1°F
4.4 Internal anti-scalding protection (qualified
contractors)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals,etc.
When supplying a shower, the appliance temperature setting
range must be adjusted by the qualified contractor to 55°C or less.
If the anti-scalding protection function is enabled and the tem-
perature limit is reached, "Tmax" flashes.
4.5 Setting the Tmax temperature limit
(childproofing)
You can adjust the temperature limit individually. If the tempera-
ture limit is enabled, "Tmax" is shown on the display.
4.5.1 Enabling the temperature limit
See chapter "Settings in the parameter menu".
4.5.2 Disabling the temperature limit
Proceed as per menu item "Enabling the temperature limit".
Turn the temperature selector to "OFF".
4.6 Assigning values to the temperature memory
buttons
Memory buttons "1" and "2" can each be assigned a preferred
temperature.
Select the preferred temperature.
To save the preferred temperature, press and hold button
"1" or "2" for more than 3seconds. The selected temperature
flashes once to confirm.
4.7 Inlet temperature information
If the appliance is operated with preheated water and the inlet
temperature exceeds the selected set temperature, the inlet tem-
perature is indicated on the second display line and flashes. The
water is not heated further.
4.8 Info menu
The appliance has an additional display where consumption values
can be shown.
4.8.1 Calling up the info menu
Briefly press "i" until "i1" appears, then continue to press "i"
to see further menus.
Exit the menu item by pressing "i" and holding for more than
5seconds. Alternatively: The system exits the menu item au-
tomatically 30seconds after the setting has been completed.
Menu Description Explanation Screen | display
I1 Flow rate The current flow rate
is shown.
Flow rate in l/min or
gpm
I2 Time The current time is
shown.
Time
I3
Energy consump-
tion
The amount of en-
ergy consumed is
shown.
Value in kWh
I4 Water consump-
tion
The amount of water
consumed is shown.
Value in m³ | gal
Note
The consumption values are calculated starting from the
last reset.