88  
D0000053280
Hook the appliance cover at the top rear into the back panel.
Pivot the appliance cover downwards. Check that the appli-
ance cover is securely fitted at both top and bottom.
Tick the selected connected load and rated voltage on the ap-
pliance cover type plate (on both sides). Use a ballpoint pen
to do this.
Secure the appliance cover with the screw.
Fit the fascia to the appliance cover.
D0000053281
Switch the mains power ON.
Note
The display activates after approximately 1minute.
Check the function of the appliance and the mini wireless
remote control.
Carry out quick commissioning for the most important set-
tings. You can also adjust the settings to your needs later via
the "Settings/ Standard settings" menu.
11.1.1 Changing the connected load
If you select a connected load other than the 21 kW factory setting
for appliances with selectable connected load, take the following
steps.
Connect the appliance to the mains voltage for the conversion.
Proceed as described in chapter "Commissioning", but switch on
the mains voltage immediately after safety switch activation.
D0000053276
1 2
1 Connected load button
2 Display
Press the connected load button briefly to wake up the dis-
play. The set connected load flashes.