ENGLISH
89
Then press the button repeatedly until the desired connected
load appears on the display. The connected load selected is
adopted immediately.
11.1.2 Mini wireless remote control
The mini wireless remote control is factory registered to the de-
vice. If no data transmission takes place during commissioning,
repeat the learning process (see chapter "Installation options/
Registering the mini wireless remote control".
11.1.3 Appliance handover
Explain the appliance function to users and familiarise them
with its operation.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over the instructions.
11.2 Recommissioning
!
Material losses
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted taking the following steps.
Isolate the appliance from the power supply; do this
by switching off the fuses or switching the device to
OFF.
Open the tap for a minimum of one minute until the
appliance and its upstream cold water inlet line are
free of air.
Switch the power supply back on, or set a tempera-
ture on the device or wireless remote control.
12. Appliance shutdown
Isolate all poles of the appliance from the power supply.
Drain the appliance (see chapter "Installation/ Maintenance/
Draining the appliance").