INSTALLATION
Specication
104|DHEConnect | DHETouch  www.stiebel-eltron.com
17.3 Hot water output
The DHW output is subject to the mains voltage, the appliance's
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate.
Connected load in kW 38 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V 400 V 415 V 5°C 10°C 15°C 20°C
16.2 7.0 8.3 10.1 12.9
19 8.2 9.7 11.8 15.1
21.7 9.4 11.1 13.5 17.2
18 7.8 9.2 11.2 14.3
21 9.1 10.7 13.0 16.7
24 10.4 12.2 14.9 19.0
19.4 8.4 9.9 12.0 15.4
22.6 9.8 11.5 14.0 17.9
25.8 11.2 13.2 16.0 20.5
24.4 10.6 12.4 15.2 19.4
27 11.7 13.8 16.8 21.4
29.1 12.6 14.8 18.1 23.1
Connected load in kW 50 °C  DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V 400 V 415 V 5°C 10°C 15°C 20°C
16.2 5.1 5.8 6.6 7.7
19 6.0 6.8 7.8 9.0
21.7 6.9 7.8 8.9 10.3
18 5.7 6.4 7.3 8.6
21 6.7 7.5 8.6 10.0
24 7.6 8.6 9.8 11.4
19.4 6.2 6.9 7.9 9.2
22.6 7.2 8.1 9.2 10.8
25.8 8.2 9.2 10.5 12.3
24.4 7.7 8.7 10.0 11.6
27 8.6 9.6 11.0 12.9
29.1 9.2 10.4 11.9 13.9
17.4 Application areas/ Conversion table
Specific electrical resistance and specific electrical conductivity.
Standard specifica-
tion at 15 °C
20°C
25°C
Resist-
ance
ρ≥
Conductivity σ
Resist-
ance
ρ≥
Conductivity σ
Resist-
ance
ρ≥
Conductivity σ
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
900 111 1111 800 125 1250 735 136 1361