12 | HM (S)| HM(S) Trend www.stiebel-eltron.com
INSTALLATION
Power supply
10.4 Sensor installation
10.4.1 Return temperature measuring
Connect an additional return sensor in combination with the
following heat pump types:
- HPA-O 3-8 CS Plus (only in combination with a buffer
cylinder)
- HPA-O 7-13 (C)(S) Premium (only in combination with a buff-
er cylinder)
- WPL 13 E/cool
- WPL 18 E/cool
- WPL 15-25 A(C)(S) (only in combination with a buffer
cylinder)
- WPL 07-17 ACS classic (only in combination with a buffer
cylinder)
- WPL 19-24 I, A (only in combination with a buffer cylinder)
Note
For heat metering with the WPL 07-17 ACS classic/
HPA-O 3-8 CS Plus in conjunction with the HM(S)
(Trend) hydraulic module, observe the section “Heat
metering with the WPL 07-17 ACS classic / HPA-O 3-8
CS Plus”.
For systems without a buffer cylinder
Fit the sensor in the heating circuit return as a contact sensor
and if necessary, downstream of any overflow valve installed.
For systems with a buffer cylinder
Fit the sensor as a return temperature sensor in the buffer
cylinder.
Installation:
The electrical connection is made at terminal X1.4.
When installing a sensor, observe the commissioning in-
structions for the heat pump manager (see chapter “Connect-
ing external components”).
10.4.2 Heat metering with the WPL 07-17 ACS classic / HPA-O
3-8 CS Plus
Note
Install the following immersion sensor for the heat
pump, in addition to the sensor described in chapter
“Return temperature measuring”.
Use the immersion sensor connected to terminal X61 for heat
metering.
D0000067540
If required, extend the sensor lead. Use a cable with a mini-
mum diameter of 0.34mm².
D0000067541