14 | HM (S)| HM(S) Trend www.stiebel-eltron.com
INSTALLATION
Commissioning
11. Commissioning
!
Material losses
To prevent the temperature falling below the dew point,
the casing must be closed during operation and undam-
aged.
A contractor must commission the appliance, make all the set-
tings at the commissioning level of the heat pump manager, and
instruct the user.
Commissioning must be carried out in accordance with these op-
erating and installation instructions and the operating and instal-
lation instructions of all components belonging to the heat pump
system. Our customer support can assist with commissioning,
which is a chargeable service.
A heat pump system can comprise many different components.
A sound knowledge of the system function is therefore essential.
Where this appliance is intended for commercial use, the rules of
the relevant Health & Safety at Work Act may be applied during
commissioning. For further details, check with your local super-
visory body; in Germany for example, this is theTÜV.
11.1 Check before commissioning the heat pump
manager
!
Material losses
When removing the appliance cap, pull the connection
plug of the programming unit out of the control panel.
D0000041465
2
1
1 Connection
2 Connector from the programming unit
!
Material losses
Take care not to pinch the power cable of the program-
ming unit when fitting the appliance cap.
Arrange the power cable in a loop and secure it with
the multi-use cable tie provided.
!
Material losses
Observe the maximum system temperature in underoor
heating systems.
Check whether the heating system is charged to the correct
pressure.
Have you closed the air vent valve of the multi-function as-
sembly (MFG) again after venting?
Have you placed and connected the outside temperature sen-
sor and the return sensor correctly?
Check whether further sensors are correctly positioned and
connected.
Check whether the power supply is connected correctly.
Check whether the signal cable to the heat pump (bus cable)
is correctly connected.
11.1.1 High limit safety cut-out
At ambient temperatures below -15 °C the high limit safety cut-out
of the multi-function assembly may respond.
Check whether the high limit safety cut-out has tripped.
D0000041470
Reset the high limit safety cut-out by pressing the reset
button.
11.2 Appliance handover
Explain the function of the appliance to users and familiarise them
with its operation.
Note
Hand over these operating and installation instructions
to the user for safe-keeping. Always carefully observe all
information in these instructions. They provide informa-
tion on safety, operation, installation and maintenance
of the appliance.