www.stiebel-eltron.com HM (S)| HM(S) Trend | 13
INSTALLATION
Power supply
If no ASL-HM connector block is used:
D0000069971
1
1 Immersion sensor
Solder the sensor well provided onto the common return
from the DHW and heating system in the building to the heat
pump.
Insert the immersion sensor into the sensor well.
Insulate the pipe in accordance with national and regional
regulations.
If an ASL-HM connector block is used:
Insert the immersion sensor into the sensor well prefitted in
the ASL-HM.
10.4.3 TAF PT immersion/contact sensor
When installing a sensor, observe the commissioning in-
structions for the heat pump manager (see chapter “Connect-
ing external components”).
10.4.4 Outside temperature sensor AFPT
When installing a sensor, observe the commissioning in-
structions for the heat pump manager (see chapter “Connect-
ing external components”).
10.5 Connecting external components
When installing external components, observe the commis-
sioning instructions for the heat pump manager (see chapter
“Connecting external components”).
10.6 Fitting the appliance cap
Fit the appliance cap in reverse order to the instructions pro-
vided in chapter “Removing the appliance cap”.
Cable with connector
D0000041465
2
1
1 Connection
2 Connector from the programming unit
Fit the connector from the programming unit in the control
panel.
!
Material losses
Take care not to pinch the power cable of the program-
ming unit when fitting the appliance cover.
Arrange the power cable in a loop again and secure
it with the multi-use cable tie provided.