6 | HM (S)| HM(S) Trend www.stiebel-eltron.com
INSTALLATION
Installation
ASL-HM
D0000041458
9.3 Minimum clearances
HM (S) | HM(S) Trend without ASL-HM
≥150
≥1000
≥70
≥400
D0000041600
Maintain the minimum clearances to enable maintenance
work on the appliance.
If the appliance is not installed in a recess, we recommend
leaving 400mm clearance on the right-hand side for the
electrical connection.
HM(S) | HM(S) Trend with ASL-HM
≥150
≥1000
≥400
≥70
D0000041599
Maintain the minimum clearances to enable maintenance
work on the appliance.
If the appliance is not installed in a recess, we recommend leav-
ing 400mm clearance on the right-hand side for the electrical
connection.
9.4 Wall mounting
General
164
D0000042865
Position the installation template horizontally at the required
installation location. The installation template can be found
in the cardboard box.
Mark the holes on the wall. Please note that the bottom two
holes are only required in combination with the ASL-HM.
Drill the holes.
Insert suitable rawl plugs into the holes.
Turn the double ended screws into the rawl plugs.
HM(S) | HM(S) Trend without ASL-HM
D0000041461
Place the appliance onto the double ended screws, followed
by the washers provided. Secure the appliance with the cor-
responding nuts.