12 | PER 18/21/24 www.stiebel-eltron.com
INSTALLATION
Installation
Preparing the power cable
160
≥ 30
26�02�02�0887
Fitting the wall mounting bracket
26�02�02�0972
Mark out the holes for drilling using the installation template.
If the appliance is to be installed with water connections on
finished walls, also mark out the fixing holes in the lower part
of the template.
Drill the holes and secure the wall mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not part
of the standard delivery).
Fit the threaded stud provided.
Fit the wall mounting bracket.
Fitting the cable grommet
26�02�02�0950
Fit the cable grommet. For connecting cables >6mm², en-
large the hole in the cable grommet.
Making the water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
26�02�02�0948
Seal and insert the twin connectors.
!
Material losses
Never use the shut-off valve in the cold water inlet to
reduce the flow rate.
Preparing the back panel
!
Material losses
If you break open the wrong knock-out in the back panel
by mistake, you must use a new back panel.
18
kW
24
21
26�02�02�0884
Break out the cable grommet knock-out in the back panel.
Deburr any sharp edges with a file if necessary.