OPERATION
Cleaning, care and maintenance
8 | PER 18/21/24 www.stiebel-eltron.com
4.2.10 Resetting to factory defaults
Press button1 and button2
simultaneously for 2seconds
Display flashes to confirm.
Anti-scalding protection and registered wireless remote controls
are not reset (for factory defaults, see chapter "Specification").
4.3 Settings on the wireless remote control
OFF
3s
D0000041708
Press 38°
Press 55°
Press +
Press -
38°C
55°C
Press 1x: Set value raised by 0.5°C.
Press 1x: Set value lowered by 0.5°C.
You can switch the appliance heater to OFF using the wireless
remote control. To do this, press the minus button for at least3sec-
onds. Press any key to switch it back on.
4.4 Further functions
4.4.1 Dynamic anti-scalding protection
The appliance is equipped with dynamic anti-scalding protection.
The user who is first to select a temperature on the appliance or
via the wireless remote control sets the temperature for the next
draw-off. No other user can increase the temperature above 43°C
in the following two minutes or during a draw-off or for two min-
utes following the end of a draw-off.
4.4.2 Anti-scalding protection
The qualified contractor can permanently limit the temperature
(see chapter "Troubleshooting/ Customer service mode"). This
prevents water from flowing out of the appliance at temperatures
which could cause injury.
4.5 Recommended settings
Saving energy
The following recommended settings will result in the lowest en-
ergy consumption:
- 38°C for basins, showers, bath
- 55°C for kitchen sinks
Thermostatic valve
If the appliance is being operated with a thermostatic valve, we
recommend setting the temperature on the appliance to maximum
(temperature selector set to 60°C). You can then select the required
temperature at the thermostatic valve.
Following an interruption to the water supply
!
Material losses
Following an interruption of the water supply the appli-
ance must be recommissioned by carrying out the follow-
ing steps, in order to prevent the destruction of the bare
wire heating system.
Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
Open the tap for one minute until the appliance and
its upstream cold water inlet line are free of air.
Switch the mains power back ON again.
5. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp cloth
is sufficient for cleaning the appliance.
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.

Table of Contents