OPERATION
Menu structure
16 |WPF | WPF cool www.stiebel-eltron.com
ELECTRIC REHEATING DUAL MODE TEMP DHW
LOWER APP LIMIT DHW
COOLING COOLING ON / OFF
COOLING MODE PASSIVE COOLING / ACTIVE COOLING
ACTIVE COOLING AREA COOLING SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
DYNAMIC
FAN COOLING SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
DYNAMIC
PASSIVE COOLING AREA COOLING SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
FAN COOLING SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
5.4.1 General
Time / Date
Here you can set the time, year, month and day.
Setting Summer time
Here you can select summer time.
At the factory, summer time is set to begin on 25March and to
end on 25October.
Contrast
Here you can set the display contrast.
Brightness
Here you can set the display brightness.
Touch sensitivity and Touch acceleration
A code is required for this adjustment.
5.4.2 Heating
Heating circuit 1 and heating circuit 2
COMFORT TEMPERATURE and ECO TEMPERATURE
Here you can select the set room temperatures for Comfort mode
and ECO mode as well as the heating curve rise for heating circuit1
and heating circuit2.
Changing the set room temperature results in a parallel shift of
the heating curve.
The actual room temperature can also be scanned, as soon as the
FE7 remote control has been connected and allocated to heating
circuit 1.
The actual room temperature can also be scanned, as soon as the
FE7 or FEK remote control has been connected and allocated to
heating circuit2.
The display HEAT CIRCUIT2 only appears if the mixer flow sensor
for heating circuit2 has been connected.MINIMUM TEMPERATURE
The set MINIMUM TEMPERATURE is safeguarded by the heating
circuit controller and will never be undershot.
MAXIMUM MIXER TEMPERATURE
Setting range 20 °C to 90°C.
This setting limits the flow temperature of the mixer circuit. For
example, if a higher set flow temperature is calculated from the
mixer circuit data, the max. set mixer flow temperature will be
used to control and regulate to this value.

Table of Contents

Other manuals for STIEBEL ELTRON WPF 13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON WPF 13 and is the answer not in the manual?

STIEBEL ELTRON WPF 13 Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelWPF 13
CategoryHeat Pump
LanguageEnglish

Related product manuals