29FR 350, FR 450, FR 480
English
Stopping the Engine
: Push the slide control to 0 (c).
At very low outside temperatures
: Motor warmlaufen lassen
As soon as engine runs:
: Blip the throttle trigger. The slide
control moves to the normal run
position # and the engine settles
down to idle speed.
: Open the throttle slightly.
: Warm up engine for brief period.
FR 450: It may be necessary to change
over to winter operation – see chapter
on "Winter Operation".
If the engine does not start
If you did not turn the choke knob to e
(warm start) quickly enough after the
engine began to fire, the engine has
flooded.
: Turn the choke knob to e
: Set the slide control, trigger
interlock and throttle trigger to the
starting throttle position.
: Start the engine by pulling the
starter rope firmly. 10 to 20 pulls
may be necessary.
If the engine still does not start
: Move the slide control 0 (c).
: Pull off the spark plug boot (5).
: Unscrew and dry off the spark plug.
: Open the throttle wide.
: Crank the engine several times with
the starter to clear the combustion
chamber.
: Refit the spark plug and connect the
spark plug boot – press it down
firmly.
: Move the slide control to START.
: Turn the choke knob to e – even if
the engine is still cold.
: Now start the engine.
Throttle cable adjustment
: Check that the throttle cable is
properly adjusted – see "Adjusting
the Throttle Cable".
Tank run completely dry before
refueling
: Press the fuel pump bulb at least
five times, even if the bulb is still
filled with fuel.
: Now start the engine.
271BA019 KN
5