N Turn the guide bar over every time
you sharpen the chain and every
time you replace the chain – this
helps avoid one-sided wear,
especially at the nose and
underside of the bar.
N Regularly clean the oil inlet hole (1),
the oilway (2) and the bar groove
(3).
N Measure the groove depth with the
scale on the filing gauge (special
accessory) – in the area used most
for cutting.
If groove depth is less than specified:
N Replace the guide bar.
The drive link tangs will otherwise
scrape along the bottom of the groove –
the cutters and tie straps will not ride on
the bar rails.
The air filter system can be adapted to
suit different operating conditions by
installing a choice of filters. Changing
the filter is quick and simple.
The saw comes standard with either a
fabric filter or a fleece filter.
Fabric filter
For normal operating conditions and
winter operation.
Fleece filter
For dry and very dusty work areas.
Taking Care of the Guide Bar
Chain
type
Chain pitch Minimum
groove depth
Picco 1/4" P 0.16" (4.0 mm)
Rapid 1/4" 0.16" (4.0 mm)
Picco 3/8" P 0.20" (5.0 mm)
Rapid 3/8"; 0.325" 0.24" (6.0 mm)
Rapid 0.404" 0.28" (7.0 mm)
Air Filter System
208BA001 KN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl MS 250C and is the answer not in the manual?

Stihl MS 250C Specifications

General IconGeneral
Engine Power2.3 kW
Displacement45.4 cm³
Guide Bar Length40 cm
Power output2.3 kW (3.1 hp)
Chain pitch3/8"

Related product manuals