EasyManua.ls Logo

Stihl RE 140 K - Removing; Installing Electrical Components; Switch Housing

Stihl RE 140 K
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- Remove shroud (see 5.1).
Note: Note circuit diagram; if
necessary, produce a drawing
clearly showing which wire
(note colour) is connected to the
respective terminals.
RE 140 K
Undo fastening screws in cover
of switch housing.
- Disconnect plug connector and
protective earth conductor.
Ensure that the serrated washer
is not lost.
- Remove switch, see 9.2.2.
- Remove cover.
Examine gasket (1) of switch
housing and replace if necessary.
Reassemble parts in reverse order.
RE 160 K
Undo fastening screws in cover
of switch housing. Ensure that
nuts are not lost.
- Remove cable lugs from switch.
- Remove switch, see 9.2.2.
- Remove cover.
Examine gasket (1) of switch
housing and replace if necessary.
Undo fastening screws of switch
housing.
Lift switch housing up, taking
care not to damage the wires.
Examine gasket (1) and replace
if necessary.
Reassemble parts in reverse order.
9.2 Removing / installing electrical components
9.2.1 Switch housing
621RA030 BL
621RA031 BL
1
621RA032 BL
1
621RA109 KN
1
621RA110 KN
24 RE 140 K, 160 K